Previous
Next
- Deye High Voltage HV Commercial 50KW Three 3 phase Hybrid Solar
- SUN-50K-SG01HP3-EU-BM4
KERNEL PARAMERERS
- Max. Charging Current (A): 50+50
- Max. Discharging Current (A): 50+50
- Number of Battery input: 2
- Charging Strategy for Li-Ion Battery: Self-adaption to BMS
BASIC SYSTEM ARCHITECTURE
The following illustration shows basic application of this inverter. It also includes following devices to have a Complete running system – Generator or Utility – PV modules Consult with your system integrator for other possible system architectures depending on your requirements. This inverter can power all kinds of appliances in home or office environment, including motor type appliances such as refrigerator and air conditioner.
KEY PRODUCT FEATURES
- Colorful touch LCD, IP65 protection degree
- 6 time periods for battery charging/discharging Max. charging/discharging current of 190A
- Max. charging/discharging current of 190A
- Max.16pcs parallel
- DC couple and AC couple to retrofit existing solar system
- Support storing energy from diesel generator
- Max. battery charge efficiency of 95.4%
- Unique Smart Load application and Grid peak shaving function
- 4ms fast transfer from on-grid to off-grid mode, ensuing the traditional fixed frequency air conditioner works well
- Certified by UL, CE, IEC, VDE, NRS, VFR, AS4777.2,CEI and INMETRO etc.
TECHNICAL PARAMETERS
Model | SUN-30K-SG01HP3-EU-BM3 | SUN-40K-SG01HP3-EU-BM4 | SUN-50K-SG01HP3-EU-BM4 |
---|---|---|---|
Battery Input Data | |||
Battery Type | Lithium-ion | ||
Battery Voltage Range(V) | 160~800 | ||
Max. Charging Current (A) | 50+50 | ||
Max. Discharging Current (A) | 50+50 | ||
Number of battery input | 2 | ||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | ||
PV String Input Data | |||
Max. DC Input Power (W) | 39000 | 52000 | 65000 |
Max. DC Input Voltage (V) | 1000 | ||
Start-up Voltage (V) | 180 | ||
MPPT Range (V) | 150-850 | ||
Full Load DC Voltage Range (V) | 360-850 | 360-850 | 450-850 |
Rated DC Input Voltage (V) | 600 | ||
PV Input Current (A) | 36+36+36 | 36+36+36 | 36+36+36+36 |
Max. PV ISC (A) | 55+55+55 | 50+50+50 | 50+50+50+50 |
Number of MPPT / Strings per MPPT | 3/2 | 4/2 | 4/2 |
AC Output Data | |||
Rated AC Output and UPS Power (W) | 30000 | 40000 | 50000 |
Max. AC Output Power (W) | 33000 | 44000 | 55000 |
AC Output Rated Current (A) | 45.5/43.5 | 60.7/58 | 75.8/72.5 |
Max. AC Output Rated Current (A) | 50/47.8 | 66.7/63.8 | 83.4/79.7 |
Max. Three-phase Unbalanced Output Current | 60 | 70 | 83.3 |
Max. Continuous AC Passthrough (A) | 200 | ||
Peak Power (off grid) | 1.5 time of rated power, 10 S | ||
Generator input/Smart load/AC couple current (A) | 45.5 / 200 / 45.5 | 60.7 / 200 / 60.7 | 75.8 / 200 / 75.8 |
Power Factor | 0.8 leading to 0.8 lagging | ||
Output Frequency and Voltage | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | ||
Grid Type | Three Phase | ||
Total Harmonic Distortion (THD) | <3% (of nominal power) | ||
DC current injection | <0.5% In | ||
Efficiency | |||
Max. Efficiency | 97.60% | ||
Euro Efficiency | 97.00% | ||
MPPT Efficiency | 99.90% | ||
Protection | |||
Integrated | PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection,Insulation Resistor | ||
Detection, Residual Current Monitoring Unit, Output Over Current Protection,Output Shorted Protection, Surge protection | |||
Output Over Voltage Protection | DC Type II/AC Type III | ||
Certififications and Standards | |||
Grid Regulation | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150 | ||
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||
General Data | |||
Operating Temperature Range (℃) | -45-60℃, >45℃ derating | ||
Cooling | Smart cooling | ||
Noise (dB) | ≤65 dB | ||
Communication with BMS | RS485; CAN | ||
Weight (kg) | 75 | ||
Size (mm) | 527W×894H×294D | ||
Protection Degree | IP65 | ||
Installation Style | Wall-mounted | ||
Warranty | 5 years |